Call Us Enquire Now
Enquire Now

Enquire Now

×
Mabtech Multiplexing High-Plex Biomarker Detection & Analysis

Mabtech Multiplexing High-Plex Biomarker Detection & Analysis

Simultaneously detect multiple biomarkers from a single sample with advanced multiplexing solutions designed for immunology, biomarker discovery, and translational research. Achieve faster, high-quality results while reducing sample volume, time, and assay complexity.






Exclusive Channel Partner

Exclusive Channel Partner

Mabtech in India

Industry Experience

Industry Experience

30+ Years Enabling Indian Labs

Pan-India Support

Pan-India Support

Installation, Training, Application & Service Support Across India

Trusted by Leading Labs

Trusted by Leading Labs

Supporting India’s leading research, academic & biopharma institutions



Applications

Mabtech EYRA™️ brings high-plex biomarker detection to any lab without the fluidics complexity of traditional multiplex systems. Using image-based confocal analysis of coded beads, a single sample yields simultaneous data on 30+ analytes — cytokines, chemokines, and other biomarkers — in one load-and-run assay. Medispec supplies and supports EYRA™️ as the exclusive Mabtech channel partner in India, with local installation, application training, and service.

Cytokine & chemokine profiling

Cytokine & chemokine profiling

Biomarker discovery

Biomarker discovery

Immune monitoring

Immune monitoring

Inflammation research

Inflammation research

Cell signaling studies

Cell signaling studies

Vaccine research

Vaccine research

Drug discovery & development

Drug discovery & development

Translational and clinical research

Translational and clinical research





Products



IMAGE-BASED MULTIPLEX ANALYSIS

EYRA™ Mabtech

Accelerate high-plex biomarker research with Mabtech EYRA™, an innovative image-based multiplex platform that combines confocal microscopy with bead-based technology for rapid, reliable analysis without the complexity of fluidics.


  • Detects 30+ analytes simultaneously from a single sample.
  • Image-based bead analysis powered by advanced confocal microscopy.
  • Zero fluidics design eliminates clogging, tubing maintenance, and wash system issues.
  • Analyzes an entire 96-well plate in less than 15 minutes.
  • No warm-up time or instrument setup required for daily operation.
  • Simple load-and-run workflow with fully automated image acquisition and analysis.
  • High sensitivity delivers accurate, quantitative multiplex biomarker measurements.
  • Reduces sample consumption while increasing throughput with scalable biomarker panels.
Best For
  • Cytokine analysis
  • Biomarker profiling
  • Immunology research
  • Translational research
  • Precision medicine
  • High-throughput multiplex assays

Mabtech EYRA™ provides fast, maintenance-free multiplex analysis with an intuitive workflow, enabling researchers to generate high-quality data while spending less time on instrument maintenance.

EYRA™ Mabtech


Why Choose Mabtech EYRA™?

Multiplex Minus the Mess
Unlike conventional bead-based multiplex systems, Mabtech EYRA™ removes the complexity of fluidics while maintaining the performance researchers expect.


30+ Analytes Measured in a Single Assay
30+ Analytes Measured in a Single Assay
Image-Based Analysis Using Confocal Microscopy
Image-Based Analysis Using Confocal Microscopy
Zero Fluidics – No Clogs & Virtually No Maintenance
Zero Fluidics – No Clogs & Virtually No Maintenance
No Warm-Up Time for Immediate Operation
No Warm-Up Time for Immediate Operation
96-Well Plate Analysis in Under 15 Minutes
96-Well Plate Analysis in Under 15 Minutes
Insert-and-Run Workflow with Automated Results
Insert-and-Run Workflow with Automated Results
Reduced Hands-On Time & Improved Productivity
Reduced Hands-On Time & Improved Productivity

Key Capabilities

High-Plex Biomarker Detection

High-Plex Biomarker Detection

Simultaneous Multi-Analyte Analysis

Simultaneous Multi-Analyte Analysis

Reduced Sample Volume Requirements

Reduced Sample Volume Requirements

Rapid Quantitative Results

Rapid Quantitative Results

High-Throughput Screening

High-Throughput Screening

Scalable Multiplex Assay Design

Scalable Multiplex Assay Design

Image-Based Bead Detection

Image-Based Bead Detection

Simple, Maintenance-Free Operation

Simple, Maintenance-Free Operation



Medispec Scientific Support

Instrument Installation & Validation
Instrument Installation & Validation
Application Training
Application Training
Workflow Optimization
Workflow Optimization
Preventive Maintenance
Preventive Maintenance
AMC Support
AMC Support
Technical Troubleshooting
Technical Troubleshooting
Assay Consultation
Assay Consultation
AMC Support
AMC Support

Trusted Across Advanced Research Laboratories

Used by leading institutions driving scientific progress across India and globally.

  • Biotech Companies
  • Pharmaceutical Organizations
  • Translational Research Centers
  • Academic Institutes
  • Diagnostics Laboratories
Across Leading Research Areas
  • Oncology
  • Immunology
  • Cardiovascular
  • Cell Therapy
  • Tissue Engineering
  • Regenerative Medicine
  • Drug Testing
  • Organoid Development

Frequently Asked Questions

Which platform should I start with if I’m new to multiplex biomarker analysis?

Mabtech EYRA™ is designed as an accessible entry point into multiplex biomarker analysis. Its load-and-run workflow, zero-fluidics technology, and automated data analysis eliminate the need for specialized training or instrument maintenance while delivering high-sensitivity quantitative results.

What’s the difference between EYRA™ and traditional bead-based multiplex systems?

 Traditional bead-based systems use fluidics to move beads individually through a laser detector, requiring regular maintenance due to tubing wear and clogging. EYRA™ uses fluidics-free confocal microscopy to image beads directly, providing the same multiplex capability with significantly reduced maintenance.

When should I choose multiplexing instead of a single-analyte ELISA?

Multiplexing is ideal when you need to measure multiple biomarkers from a limited sample volume. EYRA™ can simultaneously detect more than 30 analytes in a single well, enabling comprehensive biomarker profiling while reducing sample consumption, assay time, and reagent costs.

How many samples can EYRA™ process, and how quickly?

EYRA™ analyzes a complete 96-well plate in under 15 minutes. With no warm-up time or lengthy instrument setup, it supports both routine laboratory workflows and high-throughput biomarker screening.

How many biomarkers can EYRA™ detect in a single assay?

EYRA™ supports high-plex detection of more than 30 biomarkers simultaneously within a single well, allowing researchers to generate comprehensive cytokine and protein profiles from precious or low-volume samples.

What sample types are compatible with EYRA™?

EYRA™ is compatible with a wide range of biological samples, including serum, plasma, cell culture supernatants, and other research specimens, making it suitable for immunology, inflammation, oncology, and biomarker discovery applications.

Does EYRA™ require regular maintenance?

 No. Because EYRA™ operates without fluidics, there are no pumps, tubing, or wash systems to maintain. This greatly reduces routine maintenance and minimizes instrument downtime.

Do you provide installation, training, and technical support in India?

Yes. Medispec provides complete installation, application training, and ongoing technical support across India to help laboratories get the most from their EYRA™ multiplex biomarker analysis platform.

Get the Right High-Plex Biomarker Detection System for Your Lab

Medispec India is the exclusive channel partner of Mabtech laboratory equipment, providing local sales, installation, certification, and service support.