Call Us Enquire Now
Enquire Now

Enquire Now

×
Synoptics Syngene Gel Documentation Systems - Gel, Blot & Fluorescence Imaging


Synoptics Syngene Gel Documentation Systems - Gel, Blot & Fluorescence Imaging

Imaging solutions for DNA/RNA gels, protein gels, chemiluminescent and multiplex fluorescent Western blots – from economical entry-level darkrooms to premium, GLP/21 CFR Part 11-compliant imaging platforms. Medispec India is the authorized distributor of Syngene gel documentation, chemiluminescence, and PCR workstation systems in India, providing local sales, applications, and service support.


8
Syngene imaging & workstation models
5–24.1 MP
Camera resolution range across the portfolio
Up to 5
Independent light sources (Hi-LED multiplex modules)
GLP / 21 CFR Part 11
Compliance available across the premium range



Exclusive Channel Partner

Exclusive Channel Partner

Syngene in India

Industry Experience

Industry Experience

30+ Years Enabling Indian Labs

Pan-India Support

Pan-India Support

Installation, Training, Application & Service Support Across India

Trusted by Leading Labs

Trusted by Leading Labs

Supporting India’s leading research, academic & biopharma institutions



Applications

PCR Analysis

PCR Analysis

Western Blot Imaging

Western Blot Imaging

DNA/RNA Analysis

DNA/RNA Analysis

Protein Quantification

Protein Quantification

Molecular Diagnostics

Molecular Diagnostics





The Technology

One imaging platform, from routine gels to regulated Western blots

Every Syngene system is built around the same core promise – sharp, reproducible, publication-quality images, whether you’re documenting a simple agarose gel or running a multiplex fluorescent Western blot under GLP conditions.

High-resolution CCD/CMOS imaging

Sensitive cameras (5MP to 24.1MP) paired with motor-driven zoom or fixed lenses capture both DNA/RNA and protein gels with sharp, closely-spaced band resolution.

Multiplex Hi-LED illumination

Full-colour RGB, far-red (FR), and infrared (IR) Hi-LED modules – combined with a multi-position gantry offering up to five light sources – enable multiplex fluorescence Western blotting, chemiluminescence, stain-free imaging, and gel documentation from a single platform.

GeneSys & GeneTools software

Intuitive GeneSys capture software handles single and series chemi/fluorescence acquisition, while GeneTools delivers quantification, editing, and export – with GLP and 21 CFR Part 11 compliance plus IQOQPQ validation available on the premium range.

Contamination control for upstream PCR

Syngene’s AirClean-partnered PCR workstations and Dead Air boxes protect the sample integrity that ultimately feeds into gel and blot imaging, completing the workflow from amplification to documentation.

Which Syngene Imaging System Is Right for You?

Compare Syngene gel documentation and chemiluminescence imaging systems side by side to find the right platform for your laboratory. From routine gel documentation to high-sensitivity chemiluminescence and multiplex fluorescence imaging, each system is designed to match different research, teaching, and regulated laboratory workflows.


Feature / Instrument DigiGenius InGenius 5 NuGenius XE G:Box F3 lfb G:Box mini 6/9 G:Box mini XRQ G:Box chemi XRQ G:Box chemi XX6/9 GeneGnome XRQ
Instrument Image DigiGenius InGenius 5 NuGenius XE G:Box F3 lfb G:Box mini 6/9 G:Box mini XRQ G:Box chemi XRQ G:Box chemi XX6/9 GeneGnome XRQ
Category / System Type Gel doc Gel doc / Fluor Gel doc Gel doc / Fluor Chemi / Fluor Chemi / Fluor Chemi / Fluor Chemi / Fluor Chemi / Fluor
Image Resolution 24.1 MP 5 MP 5 / 6 / 9 MP 5 / 6 / 9 MP Premium CCD (6 / 9.1 MP) Mid-range CCD 4 MP 6 / 9.1 MP 4 MP
Bit Depth - 12 / 16 Bit 12 / 16 Bit 12 / 16 Bit 16 Bit - 16 Bit 16 Bit 16 Bit
Dynamic Range - 3.6 / 4.8 OD 3.6 / 4.8 OD 3.6 / 4.8 OD 4.8 OD - 4.8 OD 4.8 OD 4.8 OD
Lens - 6.5–39 mm F/1.4 F1.2 F1.2 F0.95 - F1.2 F0.95 F0.95
Multiplex Hi-LED (RGB / FR / IR) - - - - -
Chemiluminescence - - - Optional / Upgradeable
GLP / 21 CFR Part 11 - - - - -
Viewing / Max Sample Area 20 × 20 cm 20 × 24 cm 20 × 24 cm Max 32.5 × 24.1 cm 15 × 12 cm 18 × 14 cm Max 30.5 × 22.7 cm Max 32.3 × 25.6 cm 11 × 8 cm
Filter Positions - 1 1 7 7 - 7 7 -
DNA Gels - - -
Protein Gels - - -
Fluorescence Imaging - - -
Image Capture Software - -
Analysis Software - -
Typical Use Case Teaching & routine gel documentation Everyday fluorescence imaging Compact publication-quality gel imaging Fluorescent & protein gel imaging Everyday compact blot imaging Everyday compact blot imaging Flexible mid-range research Highest-sensitivity blot imaging Dedicated chemiluminescence imaging




Key Capabilities

High-resolution imaging

High-resolution imaging

Fluorescence detection

Fluorescence detection

Chemiluminescence workflows

Chemiluminescence workflows

Quantitative analysis

Quantitative analysis

Easy documentation & reporting

Easy documentation & reporting



Medispec Scientific Support

Instrument Installation & Validation
Instrument Installation & Validation
Application Training
Application Training
Workflow Optimization
Workflow Optimization
Preventive Maintenance
Preventive Maintenance
AMC Support
AMC Support
Technical Troubleshooting
Technical Troubleshooting
Assay Consultation
Assay Consultation
AMC Support
AMC Support

Trusted Across Advanced Research Laboratories

Used by leading institutions driving scientific progress across India and globally.

  • Biotech Companies
  • Pharmaceutical Organizations
  • Translational Research Centers
  • Academic Institutes
  • Diagnostics Laboratories
Across Leading Research Areas
  • Oncology
  • Immunology
  • Cardiovascular
  • Cell Therapy
  • Tissue Engineering
  • Regenerative Medicine
  • Drug Testing
  • Organoid Development

Frequently Asked Questions

Which gel documentation system should I start with for routine, everyday use?

 The DigiGenius is Syngene’s entry-level, economical option, purpose-built for straightforward, reliable gel documentation of nucleic acid and protein gels, making it an ideal starting point for teaching laboratories and routine research applications.

What’s the difference between a gel documentation system and a chemiluminescence/fluorescence system?

Gel documentation systems such as DigiGenius and NuGenius XE are designed for imaging DNA, RNA, and protein gels under UV or blue-light illumination. Chemiluminescence and fluorescence systems in the G:Box mini and G:Box chemi ranges add multiplex Hi-LED illumination (RGB, far-red, and infrared) with high-sensitivity cameras to support Western blot imaging, multiplex fluorescence, stain-free imaging, tissue imaging, and in-vivo fluorescence applications.

What’s the difference between the G:Box mini and G:Box chemi ranges?

 Both ranges use the same GeneSys and GeneTools software together with multiplex Hi-LED illumination. The G:Box mini models feature a compact footprint and smaller viewing area, making them ideal for laboratories with limited bench space. The G:Box chemi range offers a larger imaging area and gantry, supporting larger samples, tissue sections, multi-well plates, and advanced fluorescence imaging.

Which system offers the highest sensitivity for Western blot imaging?

The G:Box chemi XX6/XX9 is Syngene’s flagship chemiluminescence and fluorescence imaging platform. Equipped with a 6 MP or 9 MP camera and a high-performance F/0.8 lens, it delivers exceptional sensitivity for film-quality Western blot imaging without requiring a darkroom.

Are Syngene imaging systems compliant with GLP and 21 CFR Part 11?

Yes. The G:Box mini 6/9, G:Box mini XRQ, G:Box chemi XRQ, and G:Box chemi XX6/XX9 support GLP and 21 CFR Part 11 compliance, with IQ/OQ/PQ validation documentation available for laboratories operating in regulated environments.

What is a PCR workstation, and how is it different from a Dead Air box?

 A PCR workstation uses HEPA-filtered vertical laminar airflow to maintain a continuously clean working environment during PCR sample preparation, minimizing airborne contamination. A Dead Air box provides the same enclosed, UV-sterilized workspace but without active airflow, making it suitable for applications where maximum contamination control is not required.

Can these gel documentation systems be upgraded as my research needs grow?

  Yes. Systems such as the G:Box F3 lfb can be upgraded with an optional chemiluminescence module, and the entire G:Box family shares the GeneSys and GeneTools software platform, allowing users to move to more advanced models without changing their workflow.

Get the Right Gel Imaging System for Your Lab

Medispec India is the exclusive channel partner of Syngene laboratory equipment, providing local sales, installation, certification, and service support.